- 대화정밀공업은 최고 품질의 자재를 생산하기 위해 노력합니다.
- Polyurethane Resin
- Goods View
- DHP-1000 Soft Foam Type DHP-3000 Flexible Foam Type DHP-4000 Semi-Rigid Type DHP-2000 Rigid Foam Type Ultra Con High Strength Type Ultra Pack High Flexible Type
-
Polyurethane Resin
DHP-3000 Flexible Foam Type
- Price
- inquiry
- Feature & Purpose
- Single Component Flexible Polyurethane Foam
- attached file
- attached file2
This product is Hydrophilic (hydrophile property) waterstop material which is very effective for leakage of underground structure. And it is also effective for extension joint section and structure that is vulnerable by vibration. It is mainly applied in place where lots of water is. DHP-3000 is 1 component type polyurethane resin and has 700%~800% of foaming rate. It forms high density and high elasticity Cell. Especially, it does not turns into yellowish color in other word no discoloration. This is excellent product.It forms high density and elasticity Foam and its water proof is excellent. With its low viscosity, it is very easy to inject of hairline crack. It has excellent waterstop effect. It is hydrophile property that reacts even with very small amount of moisture. It forms Foam and it make possible to waterstop minute crack thoroughly. Foam also has excellent elasticity that accepts movement of concrete. Therefore it is very effective once it is applied on the place where vibration is severe. Waterstops crack leakage spot and joint section of all the concrete structure that accompanies any movements.Use for the cracks water stop of concrete structures and waterstop treatment for joint areas, wet areas and areas of considerable leaks, and can be used in the following areas.
Waterstops for leaking section of basement parking lot and underground concrete structure. Waterstops for cracked leakage section of structure that has vibration. Waterstops for leakage of concrete joint section. Waterstops for leakage section and water waste treatment that accompanies any movements. Waterstops for leakage section of parking lot ramp and for underground electric line passage. Property Data Property Data Classification Base Value Exterior Appearance Yellow Transparent Liquid Mixing Rate 1 Component Type Viscosity 300 ± 50 Specific Gravity 1.1 ± 0.1 Tensile Strength(㎏/㎠) 0.1 Elongation Percentage 80% or more Packing Unit 20kg / 10kg Foaming Percentage 800% Reaction Data on a Different Temperature Conditions Reaction Data on a Different Temperature Conditions Temperature Conditions 5℃ 15℃ 25℃ 30℃ Foaming Starts(sec) 35 27 16 13 Foaming Ends(sec) 215 165 126 105 Foaming Percentage 800 840 870 880 Viscosity 510 360 250 195 물의 혼합량에 따른 반응 자료 Respons to Mixing of Water Mixture(Resin:Water) Foaming Starts(sec) Foaming Ends(sec) Foaming Percentage Type of Foam 10 : 1 16 126 870 Elastic 10 : 3 27 143 820 Elastic 10 : 5 32 168 805 Elastic 10 : 10 41 185 780 Elastic
① It is specially designed to endure high pressure that is applied. Injected resin won't flow backward and this packer is also specially designed not to leak resin around stabilized and fixed packer.
② This is 1 component type high-pressure injection equipment that is specially manufactured to fill on a leakage and fracture spot by using polyurethane foam and epoxy injection material.Preparation Prepare around leaking and fracturing spot and fixate packer. Normally when injecting polyurethane foam, it is injected through packer generally. During the perforation use hammer drill and make holes with same diameter. External diameter of Drill Bit should be 10mm. Perforation angle between concrete surface and crack should keep 45 degree angle or under. If it is possible, then make position of perforation hole that contacts crack as thick as 1/2~2/3 of concrete thickness. If the concrete thickness is less than 10cm then directly perforate to fractured spot. If the thickness is 10cm~50cm, perforate in the distance of 1/5 thickness of the concrete. Conduct it around fractured spot with 20cm interval and perforate in zigzag. Packer Installation Select the suitable packer out of various kinds of packers that suits the most according to field circumstance. And use T-box wrench and firmly tighten up the packer to perforated hole and make sure not to bounce off by counter pressure. (It might get damaged if it is tightened too hard.) Polyurethane Injection Inject DHP-3000 High Flexible Foam Type by using high-pressure injection equipment or grease gun. Maintain initial injection pressure about 40kg/cm²÷ and keep injecting until waterstop material flows out through fractured spot. Halt injecting for a few minutes when DHP-3000 High Flexible Foam Type flows out grossly between cracks during first PACKER injection, then injected foam will foam completely and it will become as seal material. For next injection operation, DHP-3000 High Flexible Foam Type will fill up the cracks well enough. After 5 minutes, start to re-inject. You can ignore the chemicals that leaks out little bit, even you can check injection status. If the crack is very big then conduct sealing before injection. If the waterstop is injected properly, make sure to check the following steps in orders. ① Does the water inside of the crack come out caused by Polyurethane Foam Waterstop injection! ② Does the injected Foam react with water and come out from the cracks after gradually foaming! ③ Finally, does the undiluted liquid of Polyurethane Foam slides out between the cracks before it starts foaming! If it is so then the injection is properly done. Removing Packer Use vice pliers as a tool or bend off or use hammer to remove it.
If there is wet spot left then inject Polyurethane Foam again.Finishing Operation Remove DHP-3000 High Flexible Foam Type that is smeared around cracked area.
Spread with flexible sealing material (DH-CF30 Crack Cover Material)All the equipments and tools that are used for this operation should be cleaned when the operation is finished. Detergent such as M.E.K, Acetone, Xylene, Toluene and urethane thinner should be used when cleaning. If the Foam is smeared on your skin during the performance, wash it immediately with flowing water. Used injection equipment should need to be stored after filling up the hose, pump and medical fluid container with Engine Oil and hydraulic Oil.- When you treating medical fluid, make sure you wear protective helmet, goggle clothes and other protective devices.
- If the medical fluid is smeared on your skin, wash it off immediately and clean up with soapy water.
- All the hand tools and equipments that are used for this operation should be cleaned with thinner thoroughly.
- If you are working in sealed room, then make sure to conduct constraint ventilation for clean air.
- If the medical fluid is smeared on your skin and causes skin trouble, then you should go see specialist for prescription.
- If the temperature is below 5℃, then you must artificially raise up the temperature of medical fluid. This way you can get proper Pot Life.
- If the atmosphere temperature is high and the area is humid, Pot Life of medical fluid quickens. On the contrary, Pot Life will slow down in low temperature area.
- Be aware of it before you conduct the operation.Recommended temperature for storage is 10~25℃ with no moisture. Store it in cool area. Storing period is about 6 months in sealed condition however it can be corrupted according to storing area and conditions. Preferably use it as soon as possible. This product is packed with nitrogen gas. Once seal is removed, then use it as soon as possible.
Main Contents
-
Daehwa Precision
-
Mechanical injection packer
-
concrete crack injection repair
-
concrete repair kits
-
Single component Injection Pump
-
Twin Line Injection Pump
-
Acrylic Injection Pump
-
Grouting Injection Pump
-
grouting injection
-
polyurethane injection system
-
resin injection pump
-
repair of concrete
-
epoxy injections
-
epoxy injection system
-
epoxy injection systems
-
concrete repair epoxy injection
-
Water stop grouting Method
-
Reinjector Injection Method
-
Syringe Injection Method
-
concrete repair epoxy mortar